Fitting out or upgrading an office? Plan the light on the desks, not just the number of fittings.

Good office lighting puts even, glare-controlled light on the desks, not just bright light in the room. Suruhanjaya Tenaga's energy-audit guideline, as quoted on ClickBina's lighting design guide, recommends about 300–400 lux for general offices. Use LED panels or anti-glare fittings laid out to the desks, a neutral 4000 K colour temperature, zones and sensors so empty rooms are not lit, and positions agreed with the ceiling grid before it goes up. A site visit is RM150, waived if you go ahead.
Staff spend the whole working day under the office lighting, most of it looking at screens and paper. Lighting that is too dim, too uneven or full of glare causes tired eyes and headaches, and lighting that burns all day in empty rooms wastes power. A fit-out is the cheapest time to get it right, because the ceiling is open and the wiring is being laid anyway.
The design does not need to be complicated. It needs a target level for each area, the right fittings, positions that suit the desks, and sensible switching.
Light falling on a surface is measured in lux. ClickBina's lighting design guide quotes Suruhanjaya Tenaga's building energy-audit guideline, which lists recommended average illuminance of about 300–400 lux for general offices, shops and reading or writing, and about 100 lux for corridors, passageways and stairs. The guideline references MS 1525, a code of practice for non-residential buildings.
Two practical points follow. The target is measured where the work happens, on the desk, not at the ceiling. And it is an average, so the layout matters as much as the fittings: dark gaps between rows of desks are what staff notice. To turn a lux target into a number of fittings, use ClickBina's lux and lumen calculator.
| Fitting | Where it suits | Watch for |
|---|---|---|
| Recessed LED panel | Open offices and meeting rooms with a suspended grid ceiling | Glare rating and diffuser quality; even spacing over desks |
| Anti-glare LED downlight | Plasterboard ceilings, reception, corridors, directors' rooms | Deep recess heads so the source is not seen when seated |
| Linear suspended or surface fitting | Open ceilings and long desk rows | Aligned with desk rows, not across them |
| Track lighting | Feature walls, reception displays | Aim away from screens and faces |
| Task lamp | Detailed desk work, drawing, checking documents | Adds light where it is needed without over-lighting the room |
For most SME offices the choice is simple: panels in a grid ceiling over the work areas, and anti-glare downlights where the ceiling is plasterboard.
Glare is the main complaint in badly lit offices. The lighting design guide recommends anti-glare heads with a deep recess, rated UGR below 19, or positioning fittings so the source is not in direct view when seated. In an office that means:
The lighting design guide explains that neutral-cool 4000 K helps with concentration and visual accuracy in workspaces, while warm white suits spaces for relaxing. For an office that usually means 4000 K in work areas and meeting rooms, with a warmer tone allowed in a lounge or pantry. Keep one colour temperature within a room so fittings do not look mismatched. The same guide suggests a colour rendering index of 80+ for general areas.
| Zone | Lighting approach | Controls |
|---|---|---|
| Open office | Panels or linear fittings laid out to the desk rows | Switched by row, window row separately |
| Meeting rooms | Even, glare-controlled light; dimmable for screens | Occupancy sensor or dimmer |
| Reception | Downlights plus feature lighting on the logo wall | Timer or reception switch |
| Pantry | Bright over counters, softer over seating | Local switch or sensor |
| Corridors and stores | Lower level, even coverage | Occupancy sensors |
| Server or comms room | Simple, bright enough to work on racks | Local switch |
ClickBina's office ceiling guide explains that lights, grilles and detectors drop into tile positions in a mineral-fibre grid, which makes layout changes quick; that plasterboard is the practical way to build coves and lighting troughs; and that an open ceiling needs lighting suspended or track-mounted rather than recessed. Its advice applies directly: agree the light, grille, sprinkler and detector positions with the grid or board layout so nothing lands on a joint.
New circuits, switching and sensors are electrical work. ClickBina coordinates it with the electrician during the fit-out rather than treating it as a decorating item.
Not every lighting job is a full fit-out. In an occupied office the usual choices are a like-for-like swap of old fluorescent fittings for LED panels in the same grid positions, or a re-layout where desks have moved and the old fittings no longer sit over the work. A swap is quicker and cheaper; a re-layout fixes dark desks and glare that a swap would only repeat. Either way, walk the floor first with the staff who sit there, note the dark spots and the screens that reflect a fitting, and work zone by zone or after hours so the office keeps running. Take the chance to add sensors in meeting rooms and stores while the ceiling tiles are out.
| Item | Indicative price | Source guide |
|---|---|---|
| Recessed LED downlight, per point (supply and install) | RM60 – RM150 | Lighting design guide |
| New wiring point or lighting circuit | RM120 – RM250 per point | Lighting design guide |
| Dimmer switch | RM80 – RM200 per switch | Lighting design guide |
| Flat gypsum board ceiling (for downlight areas) | RM8 – RM11 per sq ft | Office ceiling guide |
WhatsApp us your job details for a quote — we reply within the hour.
💬 WhatsApp for a quoteThese are ClickBina's published indicative Klang Valley ranges for 2026. LED panel prices vary widely by make and rating, so panels are priced from the layout.
ClickBina handles commercial renovation and fit-out works and coordinates the trades, including the ceiling, the electrical works and the lighting layout. WhatsApp us your job details for a quote:
We reply within the hour, the price we agree is a flat price with no hidden charges, and a site visit is RM150, waived if you go ahead.
Methodology: every lux figure and RM figure is quoted unchanged from the ClickBina guides named above (indicative 2026, Klang Valley).